We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount, AEGIS SGR/02036ET3E256T-W22G WEG 20HP General Purpose Electric Motor, 3600RPM

Product ID: 02036ET3E256T-W22G

02036ET3E256T-W22G WEG 20HP General Purpose Electric Motor, 3600RPM

MFG: WEG Electric Corporation
MFG Part Number: 02036ET3E256T-W22G

Selected accessories will also be added to cart
$1,996.50 / Each
Quantity:
IC411 - TEFC, IP55, 254T/256T Frame, 230/460/380VAC 50/60Hz 3 Phase, 14855771, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 1-5/8" Keyed Shaft, AEGIS Shaft Grounding Ring

Electric Motors

Frame 254/6T
Output 20 HP (15 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3525 rpm
Slip 2.08 %
Rated voltage 230/460 V
Rated current 46.4/23.2 A
L. R. Amperes 283/142 A
LRC 6.1x(Code G)
No load current 13.0/6.50 A
Rated torque 29.8 ft.lb
Locked rotor torque 200 %
Breakdown torque 240 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 1.54 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 329 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
90.7  91.0  91.0 

Power factor

50% 75% 100%
0.80  0.87  0.89 
Frame 254/6T
Output 15 HP (11 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2935 rpm
Slip 2.17 %
Rated voltage 380 V
Rated current 20.4 A
L. R. Amperes 141 A
LRC 6.9x(Code G)
No load current 6.20 A
Rated torque 26.8 ft.lb
Locked rotor torque 220 %
Breakdown torque 260 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 1.54 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 329 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
90.6  90.9  91.2 

Power factor

50% 75% 100%
0.78  0.87  0.90 
Frame 254/6T
Output 15 HP (11 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2945 rpm
Slip 1.83 %
Rated voltage 400 V
Rated current 19.6 A
L. R. Amperes 151 A
LRC 7.7x(Code H)
No load current 6.60 A
Rated torque 26.7 ft.lb
Locked rotor torque 240 %
Breakdown torque 280 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 1.54 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 329 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
90.4  91.2  91.2 

Power factor

50% 75% 100%
0.75  0.85  0.89 
Frame 254/6T
Output 15 HP (11 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2950 rpm
Slip 1.67 %
Rated voltage 415 V
Rated current 19.1 A
L. R. Amperes 155 A
LRC 8.1x(Code J)
No load current 6.90 A
Rated torque 26.7 ft.lb
Locked rotor torque 270 %
Breakdown torque 310 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 1.54 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 329 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
89.8  91.1  91.2 

Power factor

50% 75% 100%
0.73  0.84  0.88 
Frame 254/6T
Output 20 HP (15 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2885 rpm
Slip 3.83 %
Rated voltage 380 V
Rated current 28.9 A
L. R. Amperes 147 A
LRC 5.1x(Code E)
No load current 6.20 A
Rated torque 36.4 ft.lb
Locked rotor torque 160 %
Breakdown torque 190 %
Locked rotor time 12s (cold) 7s (hot)
Moment of inertia (J) 1.54 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 329 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
87.2  87.5  87.5 

Power factor

50% 75% 100%
0.86  0.89  0.90 
Frame 254/6T
Output 20 HP (15 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2905 rpm
Slip 3.17 %
Rated voltage 400 V
Rated current 27.2 A
L. R. Amperes 155 A
LRC 5.7x(Code F)
No load current 6.60 A
Rated torque 36.2 ft.lb
Locked rotor torque 180 %
Breakdown torque 210 %
Locked rotor time 16s (cold) 9s (hot)
Moment of inertia (J) 1.54 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 329 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
89.2  89.5  89.5 

Power factor

50% 75% 100%
0.84  0.88  0.89 
Frame 254/6T
Output 20 HP (15 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2915 rpm
Slip 2.83 %
Rated voltage 415 V
Rated current 26.2 A
L. R. Amperes 160 A
LRC 6.1x(Code G)
No load current 6.90 A
Rated torque 36.0 ft.lb
Locked rotor torque 200 %
Breakdown torque 229 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 1.54 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 329 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
89.2  89.5  89.5 

Power factor

50% 75% 100%
0.82  0.87  0.89 

Features

Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole NPT 1 1/2" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Single 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12