Product ID: FRN007AR1L-2U

FRN007AR1L-2U 7.5 HP Fuji HVAC Variable Frequency Drive (VFD)

MFG: Fuji Electric Corp. of America
MFG Part Number: FRN007AR1L-2U

Selected accessories will also be added to cart
$1,180.80 / Each
Quantity:
208/230V, 50/60Hz, Single or 3 Phase Input (0-230V, 0-120Hz, 3-Phase Output), IP55/UL Type 12 Enclosure, 23.00" x 7.99" x 10.30" (H x W x D)

Description

Fuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.

Developed with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations

Fuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results.

Specifications

ManufacturerFuji Electric
Model NumberFRN007AR1L-2U
EnclosureUL/NEMA Type 12
IP55
Voltage208/230VAC 60Hz
HP Rating3 HP with Single Phase Input
7.5 HP with 3-Phase Input
Rated Current10.5 Amps with Single Phase Input
27.0 Amps with 3-Phase Input
Weight40 lbs
Dimensions7.99" x 23.00" x 10.30" (W x H x D)
Warranty3 Years from date of shipment

Detailed Specifications

Nominal Applied Motor (Rated Output)2 HP with Single Phase Input at 208VAC
3 HP with Single Phase Input at 230VAC
7.5 HP with 3-Phase Input
Rated Output Capacity4.1 kVA with Single Phase Input
10 kVA with 3-Phase Input
Rated Output Current10.5 Amps with Single Phase Input
27 Amps with 3-Phase Input
Output Frequency120Hz Maximum
Output StabilityAnalog Setting: ±0.2% of Maximum Frequency
Digital Setting: ±0.01% of Maximum Frequency (By Keypad)
Rated VoltageThree Phase, 200 to 240VAC (with AVR Function)
Output Overload Capability110% for 1 Minute
(Overload capability interval : IEC 61800-2 compliant)
Rated Input Frequency50, 60 Hz
Main Power Supply InputThree Phase, 200 to 240VAC, 50/60Hz
Rated Input Current18.0 Amps
Required Input Power Supply Capacity4.2 kVA with Single Phase Input
7.2 kVA with 3-Phase Input
Auxiliary Control Power SupplySingle Phase, 200 to 240VAC, 50/60Hz
Auxiliary Main Power Supply-
Voltage & Frequency VariationsVoltage: +10 to -15%
Interphase Voltage Unbalance: 2% or less
Frequency: +5 to -5%
Braking Torque20 %
DC Injection BrakingStarting frequency:0.0 to 60.0Hz
Braking time:0.0 to 30.0s
Braking level:0 to 60%
EMC FilterBuilt-In
EMC standards compliance : Category C2 (emission) / 2nd Env. (Immunity)
DC ReactorBuilt-in (IEC/EN 61000-3-2, IEC/EN 61000-3-12)
Power Factor (at Rated Load)>0.98 Displacement P.F. (cosf)
>=0.90 True Power Factor
Efficiency97 % at Rated Load
EnclosureIEC/EN 60529: IP55
UL 50: UL Type 12
Cooling MethodFan Cooling
Weight/Mass18 kg
Ambient TemperatureNEMA/UL Type 12: -10 to 40°C (14 to 104°F)
Storage Temperature-25 to 70°C (-13 to 158°F)
Relative Humidity5 to 95% RH (Without Condensation)
Installation LocationIEC60664-1 Pollution Degree 2
(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)
Indoor Use Only
Altitude0 to 3,300ft (1,000m)
3,300ft (1,000m) to 9,900ft (3,000m) with Derating

Features

Control Inputs & Outputs
  • 9 Digital Inputs: X1 – X7, FWD, & REV Programmable
    67 Selectable Functions
  • 2 Safety Input (dedicated): EN1, EN2
  • 3 Analog Inputs: (2) 0 to +10Vdc & (1) 4 to 20mA
  • 6 Digital Outputs: (2) Relays (1 Form C & 1 Form A) & (4) Transistor
    77 Selectable Functions
  • 2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA
    43 Selectable Functions
  • 2 RS-485 Connections: RJ45 Keypad Port & RS485 Control Terminal Block Connections
  • 24Vdc Output Terminal: Rated 200mA
  • Keypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed

Robust Design
  • Nickel (Ni) & Tin (Sn) Plated Bus Bars
  • Conformal Coated PCBs
  • Cooling Fan Board Coating + Anti-Rust Protection
  • 10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal

Flexibility & Functionality
  • Removable Control Terminal Block
  • CE Filter Built-In for All Models
  • DCR for All Models
  • PC Programming & Troubleshooting Software
  • USB Port on Control Card
  • Real Time Clock
  • Customizable Logic
  • Automatic Energy Savings Control
  • 4-PID Controllers
  • Fire Mode
  • Catch a Spinning Motor
  • Filter Clogging Prevention/Reversing Operation
  • Wet-Bulb Temperature Presumption Control
  • Selectable “Light” Alarms
  • PID Units of Measurement Display
  • Password
  • 3 Option Card Ports Built-In
  • Single Phase Input
  • BACnet MS/TP, Metasys N2, Modbus RTUD Embedded

Safety & Standards
  • Safety Input
  • UL 508C, CE
  • UL Plenum Rating
  • RoHS
  • SEMI F47-0706

Codes and Standards

  • UL508C
  • C22.2 No.14,
  • EN61800-5-1:2007

Options

    Communication Options
  • Ethernet
  • CC-Link
  • LONWORKS
  • DeviceNet
  • Profibus DP
  • CANopen

    I/O Options
  • Keypad with USB Port
  • Relay Output
  • Analog Inputs and Outputs
  • Temperature Sensor Input

Dimensions

W 203 mm
7.99"
H 585 mm
23.03"
D 262 mm
10.31"
D1 162 mm
6.38"
D2 100 mm
3.94"
W1 158 mm
6.22"
W2 22.5 mm
0.89"
H1 571 mm
22.48"
H2 7 mm
0.28"
H3 -
M 2x 8 mm diameter
2x 0.31" diameter
N 8 mm
0.31"