We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount/25018ET3E505T-W22 WEG 250HP General Purpose Electric Motor, 1800RPM

Product ID: 25018ET3E505T-W22

25018ET3E505T-W22 WEG 250HP General Purpose Electric Motor, 1800RPM

MFG: WEG Electric Corporation
MFG Part Number: 25018ET3E505T-W22

Selected accessories will also be added to cart
$20,102.25 / Each
Quantity:
IC411 - TEFC, IP55, 504T/505T Frame, 230/460/380VAC 50/60Hz 3 Phase, 12566462, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 3-5/8" Keyed Shaft

Electric Motors

Frame 504/5T
Output 250 HP (185 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1785 rpm
Slip 0.83 %
Rated voltage 230/460 V
Rated current 554/277 A
L. R. Amperes 3601/1801 A
LRC 6.5x(Code G)
No load current 170/85.0 A
Rated torque 735 ft.lb
Locked rotor torque 229 %
Breakdown torque 220 %
Locked rotor time 36s (cold) 20s (hot)
Moment of inertia (J) 89.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 75.0 dB(A)
Approx. weight³ 2588 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.8  96.2  96.2 

Power factor

50% 75% 100%
0.78  0.85  0.87 
Frame 504/5T
Output 200 HP (150 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1490 rpm
Slip 0.67 %
Rated voltage 380 V
Rated current 270 A
L. R. Amperes 1593 A
LRC 5.9x(Code F)
No load current 71.2 A
Rated torque 705 ft.lb
Locked rotor torque 200 %
Breakdown torque 220 %
Locked rotor time 66s (cold) 37s (hot)
Moment of inertia (J) 89.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 71.0 dB(A)
Approx. weight³ 2588 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.2  95.8  95.8 

Power factor

50% 75% 100%
0.81  0.87  0.88 
Frame 504/5T
Output 200 HP (150 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1490 rpm
Slip 0.67 %
Rated voltage 400 V
Rated current 257 A
L. R. Amperes 1696 A
LRC 6.6x(Code G)
No load current 76.2 A
Rated torque 705 ft.lb
Locked rotor torque 220 %
Breakdown torque 250 %
Locked rotor time 61s (cold) 34s (hot)
Moment of inertia (J) 89.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 71.0 dB(A)
Approx. weight³ 2588 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.1  95.8  95.8 

Power factor

50% 75% 100%
0.79  0.86  0.88 
Frame 504/5T
Output 200 HP (150 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1490 rpm
Slip 0.67 %
Rated voltage 415 V
Rated current 250 A
L. R. Amperes 1775 A
LRC 7.1x(Code H)
No load current 80.0 A
Rated torque 705 ft.lb
Locked rotor torque 240 %
Breakdown torque 270 %
Locked rotor time 57s (cold) 32s (hot)
Moment of inertia (J) 89.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 71.0 dB(A)
Approx. weight³ 2588 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.0  95.8  95.8 

Power factor

50% 75% 100%
0.77  0.85  0.87 
Frame 504/5T
Output 250 HP (185 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1480 rpm
Slip 1.33 %
Rated voltage 380 V
Rated current 339 A
L. R. Amperes 1729 A
LRC 5.1x(Code E)
No load current 84.0 A
Rated torque 887 ft.lb
Locked rotor torque 180 %
Breakdown torque 180 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 89.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 71.0 dB(A)
Approx. weight³ 2588 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.8  95.8  95.4 

Power factor

50% 75% 100%
0.82  0.86  0.87 
Frame 504/5T
Output 250 HP (185 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1485 rpm
Slip 1.00 %
Rated voltage 400 V
Rated current 322 A
L. R. Amperes 1803 A
LRC 5.6x(Code E)
No load current 90.0 A
Rated torque 884 ft.lb
Locked rotor torque 200 %
Breakdown torque 200 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 89.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 71.0 dB(A)
Approx. weight³ 2588 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.8  95.8  95.4 

Power factor

50% 75% 100%
0.80  0.86  0.87 
Frame 504/5T
Output 250 HP (185 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1485 rpm
Slip 1.00 %
Rated voltage 415 V
Rated current 309 A
L. R. Amperes 1885 A
LRC 6.1x(Code F)
No load current 95.0 A
Rated torque 884 ft.lb
Locked rotor torque 220 %
Breakdown torque 220 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 89.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 71.0 dB(A)
Approx. weight³ 2588 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.8  95.8  95.8 

Power factor

50% 75% 100%
0.78  0.85  0.87 

Features

Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole 2xNPT 3" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 4140 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12