We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount/15012ET3E447T-W22 WEG 150HP General Purpose Electric Motor, 1200RPM

Product ID: 15012ET3E447T-W22

15012ET3E447T-W22 WEG 150HP General Purpose Electric Motor, 1200RPM

MFG: WEG Electric Corporation
MFG Part Number: 15012ET3E447T-W22

Selected accessories will also be added to cart
$15,479.25 / Each
Quantity:
IC411 - TEFC, IP55, 445T/447T Frame, 230/460/380VAC 50/60Hz 3 Phase, 11626903, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 3-3/8" Keyed Shaft

Electric Motors

Frame 445/7T
Output 150 HP (110 kW)
Number of Poles 6
Frequency 60 Hz
Rated speed 1189 rpm
Slip 0.92 %
Rated voltage 230/460 V
Rated current 352/176 A
L. R. Amperes 2179/1090 A
LRC 6.2x(Code G)
No load current 136/68.0 A
Rated torque 662 ft.lb
Locked rotor torque 240 %
Breakdown torque 250 %
Locked rotor time 36s (cold) 20s (hot)
Moment of inertia (J) 134 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2212 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.0  95.4  95.8 

Power factor

50% 75% 100%
0.67  0.78  0.82 
Frame 445/7T
Output 125 HP
Number of Poles 6
Frequency 50 Hz
Rated speed 989 rpm
Slip 1.10 %
Rated voltage 380 V
Rated current 174 A
L. R. Amperes 1042 A
LRC 6.0x(Code F)
No load current 67.0 A
Rated torque 664 ft.lb
Locked rotor torque 229 %
Breakdown torque 240 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 134 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2212 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.8  95.1  94.9 

Power factor

50% 75% 100%
0.67  0.79  0.83 
Frame 445/7T
Output 125 HP
Number of Poles 6
Frequency 50 Hz
Rated speed 990 rpm
Slip 1.00 %
Rated voltage 400 V
Rated current 167 A
L. R. Amperes 1083 A
LRC 6.5x(Code G)
No load current 72.0 A
Rated torque 663 ft.lb
Locked rotor torque 260 %
Breakdown torque 270 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 134 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2212 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.5  95.1  95.1 

Power factor

50% 75% 100%
0.64  0.76  0.82 
Frame 445/7T
Output 125 HP
Number of Poles 6
Frequency 50 Hz
Rated speed 990 rpm
Slip 1.00 %
Rated voltage 415 V
Rated current 165 A
L. R. Amperes 1152 A
LRC 7.0x(Code H)
No load current 78.0 A
Rated torque 663 ft.lb
Locked rotor torque 280 %
Breakdown torque 290 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 134 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2212 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.5  95.1  95.1 

Power factor

50% 75% 100%
0.60  0.74  0.80 
Frame 445/7T
Output 150 HP (110 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 984 rpm
Slip 1.60 %
Rated voltage 380 V
Rated current 211 A
L. R. Amperes 1053 A
LRC 5.0x(Code E)
No load current 67.0 A
Rated torque 800 ft.lb
Locked rotor torque 190 %
Breakdown torque 200 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 134 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2212 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.0  95.0  94.5 

Power factor

50% 75% 100%
0.73  0.82  0.84 
Frame 445/7T
Output 150 HP (110 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 400 V
Rated current 201 A
L. R. Amperes 1107 A
LRC 5.5x(Code F)
No load current 74.0 A
Rated torque 800 ft.lb
Locked rotor torque 200 %
Breakdown torque 229 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 134 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2212 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.0  95.0  95.0 

Power factor

50% 75% 100%
0.70  0.80  0.83 
Frame 445/7T
Output 150 HP (110 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 986 rpm
Slip 1.40 %
Rated voltage 415 V
Rated current 196 A
L. R. Amperes 1179 A
LRC 6.0x(Code G)
No load current 78.0 A
Rated torque 799 ft.lb
Locked rotor torque 220 %
Breakdown torque 250 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 134 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 2212 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.0  95.0  95.0 

Power factor

50% 75% 100%
0.67  0.78  0.82 

Features

Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole 2xNPT 3" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 4140 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C3) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12 
Fan material Plastic 
Screw cap CARBON STEEL SAE 1010/20 
NDE bearing Seal WSeal 
DE bearing Seal WSeal 
Cable Press Material Sem