We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount/10018ET3E405TF3-W22 WEG 100HP General Purpose Electric Motor, 1800RPM

Product ID: 10018ET3E405TF3-W22

10018ET3E405TF3-W22 WEG 100HP General Purpose Electric Motor, 1800RPM

MFG: WEG Electric Corporation
MFG Part Number: 10018ET3E405TF3-W22

Selected accessories will also be added to cart
$9,030.00 / Each
Quantity:
IC411 - TEFC, IP55, 404T/405T Frame, 230/460/380VAC 50/60Hz 3 Phase, 12367540, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, F-3 Terminal Box Mounting, 2-7/8" Keyed Shaft

Electric Motors

Frame 404/5T
Output 100 HP (75 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1780 rpm
Slip 1.11 %
Rated voltage 230/460 V
Rated current 226/113 A
L. R. Amperes 1650/825 A
LRC 7.3x(Code H)
No load current 76.0/38.0 A
Rated torque 295 ft.lb
Locked rotor torque 240 %
Breakdown torque 260 %
Locked rotor time 23s (cold) 13s (hot)
Moment of inertia (J) 29.9 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 68.0 dB(A)
Approx. weight³ 1171 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.0  95.0  95.4 

Power factor

50% 75% 100%
0.77  0.84  0.87 
Frame 404/5T
Output 75 HP (55 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1485 rpm
Slip 1.00 %
Rated voltage 380 V
Rated current 102 A
L. R. Amperes 785 A
LRC 7.7x(Code H)
No load current 37.6 A
Rated torque 265 ft.lb
Locked rotor torque 260 %
Breakdown torque 280 %
Locked rotor time 16s (cold) 9s (hot)
Moment of inertia (J) 29.9 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 1171 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.0  94.4  95.0 

Power factor

50% 75% 100%
0.72  0.83  0.86 
Frame 404/5T
Output 75 HP (55 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1485 rpm
Slip 1.00 %
Rated voltage 400 V
Rated current 98.3 A
L. R. Amperes 826 A
LRC 8.4x(Code J)
No load current 40.1 A
Rated torque 265 ft.lb
Locked rotor torque 280 %
Breakdown torque 310 %
Locked rotor time 16s (cold) 9s (hot)
Moment of inertia (J) 29.9 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 1171 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.9  94.5  95.0 

Power factor

50% 75% 100%
0.69  0.81  0.85 
Frame 404/5T
Output 75 HP (55 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1485 rpm
Slip 1.00 %
Rated voltage 415 V
Rated current 95.9 A
L. R. Amperes 854 A
LRC 8.9x(Code K)
No load current 42.0 A
Rated torque 265 ft.lb
Locked rotor torque 290 %
Breakdown torque 330 %
Locked rotor time 16s (cold) 9s (hot)
Moment of inertia (J) 29.9 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 1171 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.6  94.5  95.0 

Power factor

50% 75% 100%
0.66  0.79  0.84 
Frame 404/5T
Output 100 HP (75 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 380 V
Rated current 138 A
L. R. Amperes 814 A
LRC 5.9x(Code F)
No load current 37.6 A
Rated torque 357 ft.lb
Locked rotor torque 190 %
Breakdown torque 210 %
Locked rotor time 16s (cold) 9s (hot)
Moment of inertia (J) 29.9 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 1171 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.5  94.1  93.6 

Power factor

50% 75% 100%
0.82  0.86  0.88 
Frame 404/5T
Output 100 HP (75 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 400 V
Rated current 131 A
L. R. Amperes 852 A
LRC 6.5x(Code G)
No load current 40.1 A
Rated torque 356 ft.lb
Locked rotor torque 210 %
Breakdown torque 229 %
Locked rotor time 16s (cold) 9s (hot)
Moment of inertia (J) 29.9 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 1171 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.5  94.5  94.1 

Power factor

50% 75% 100%
0.79  0.85  0.88 
Frame 404/5T
Output 100 HP (75 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 415 V
Rated current 127 A
L. R. Amperes 902 A
LRC 7.1x(Code H)
No load current 42.0 A
Rated torque 356 ft.lb
Locked rotor torque 220 %
Breakdown torque 250 %
Locked rotor time 16s (cold) 9s (hot)
Moment of inertia (J) 29.9 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 1171 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.5  94.5  94.5 

Power factor

50% 75% 100%
0.77  0.84  0.87 

Features

Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole NPT 3" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 4140 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12