We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount/10009ET3E445T-W22 WEG 100HP General Purpose Electric Motor, 900RPM

Product ID: 10009ET3E445T-W22

10009ET3E445T-W22 WEG 100HP General Purpose Electric Motor, 900RPM

MFG: WEG Electric Corporation
MFG Part Number: 10009ET3E445T-W22

Selected accessories will also be added to cart
$20,241.00 / Each
Quantity:
IC411 - TEFC, IP55, 444T/445T Frame, 230/460/380VAC 60Hz 3 Phase, 14334990, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 3-3/8" Keyed Shaft

Electric Motors

Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 8
Frequency 60 Hz
Rated speed 890 rpm
Slip 1.11 %
Rated voltage 230/460 V
Rated current 254/127 A
L. R. Amperes 1524/762 A
LRC 6.0x(Code G)
No load current 112/56.0 A
Rated torque 590 ft.lb
Locked rotor torque 190 %
Breakdown torque 220 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 1599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.6  94.1  94.1 

Power factor

50% 75% 100%
0.63  0.74  0.79 
Frame 444/5T
Output 75 HP (55 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 740 rpm
Slip 1.33 %
Rated voltage 380 V
Rated current 118 A
L. R. Amperes 717 A
LRC 6.1x(Code G)
No load current 55.0 A
Rated torque 532 ft.lb
Locked rotor torque 200 %
Breakdown torque 229 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 1599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.9  93.4  93.2 

Power factor

50% 75% 100%
0.59  0.72  0.78 
Frame 444/5T
Output 75 HP (55 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 740 rpm
Slip 1.33 %
Rated voltage 400 V
Rated current 116 A
L. R. Amperes 778 A
LRC 6.7x(Code J)
No load current 61.0 A
Rated torque 532 ft.lb
Locked rotor torque 229 %
Breakdown torque 270 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 1599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.9  93.0  93.2 

Power factor

50% 75% 100%
0.55  0.68  0.75 
Frame 444/5T
Output 75 HP (55 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 740 rpm
Slip 1.33 %
Rated voltage 415 V
Rated current 115 A
L. R. Amperes 806 A
LRC 7.0x(Code J)
No load current 67.0 A
Rated torque 532 ft.lb
Locked rotor torque 250 %
Breakdown torque 290 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 1599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.2  92.6  93.1 

Power factor

50% 75% 100%
0.51  0.65  0.73 
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 735 rpm
Slip 2.00 %
Rated voltage 380 V
Rated current 152 A
L. R. Amperes 714 A
LRC 4.7x(Code E)
No load current 55.0 A
Rated torque 714 ft.lb
Locked rotor torque 150 %
Breakdown torque 170 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 1599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.6  93.0  92.4 

Power factor

50% 75% 100%
0.69  0.78  0.81 
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 740 rpm
Slip 1.33 %
Rated voltage 400 V
Rated current 147 A
L. R. Amperes 779 A
LRC 5.3x(Code F)
No load current 61.0 A
Rated torque 710 ft.lb
Locked rotor torque 170 %
Breakdown torque 200 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 1599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.0  93.0  93.0 

Power factor

50% 75% 100%
0.65  0.75  0.79 
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 740 rpm
Slip 1.33 %
Rated voltage 415 V
Rated current 144 A
L. R. Amperes 806 A
LRC 5.6x(Code G)
No load current 67.0 A
Rated torque 710 ft.lb
Locked rotor torque 190 %
Breakdown torque 220 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 1599 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  93.0  93.0 

Power factor

50% 75% 100%
0.61  0.73  0.78 

Features

Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole 2xNPT 3" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 4140 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12