We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount, AEGIS SGR/02536ET3E284TS-W22G WEG 25HP General Purpose Electric Motor, 3600RPM

Product ID: 02536ET3E284TS-W22G

02536ET3E284TS-W22G WEG 25HP General Purpose Electric Motor, 3600RPM

MFG: WEG Electric Corporation
MFG Part Number: 02536ET3E284TS-W22G

Selected accessories will also be added to cart
$2,481.00 / Each
Quantity:
IC411 - TEFC, IP55, 284TS/286TS Frame, 50/60Hz 3 Phase, 12769919, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, AEGIS Shaft Grounding Ring, 1-5/8" Keyed Shaft

Electric Motors

Frame 284/6TS
Output 25 HP (18.5 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3545 rpm
Slip 1.53 %
Rated voltage 230/460 V
Rated current 57.6/28.8 A
L. R. Amperes 363/181 A
LRC 6.3x(Code G)
No load current 16.0/8.00 A
Rated torque 37.0 ft.lb
Locked rotor torque 200 %
Breakdown torque 250 %
Locked rotor time 30s (cold) 17s (hot)
Moment of inertia (J) 2.69 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 399 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.0  91.7  91.7 

Power factor

50% 75% 100%
0.79  0.86  0.88 
Frame 284/6TS
Output 20 HP (15 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2945 rpm
Slip 1.83 %
Rated voltage 380 V
Rated current 27.9 A
L. R. Amperes 173 A
LRC 6.2x(Code G)
No load current 8.00 A
Rated torque 35.7 ft.lb
Locked rotor torque 200 %
Breakdown torque 240 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 2.69 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 399 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
90.2  90.7  91.9 

Power factor

50% 75% 100%
0.79  0.86  0.89 
Frame 284/6TS
Output 20 HP (15 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2950 rpm
Slip 1.67 %
Rated voltage 400 V
Rated current 26.8 A
L. R. Amperes 185 A
LRC 6.9x(Code H)
No load current 8.50 A
Rated torque 35.6 ft.lb
Locked rotor torque 229 %
Breakdown torque 280 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 2.69 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 399 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
90.3  91.1  91.9 

Power factor

50% 75% 100%
0.77  0.85  0.88 
Frame 284/6TS
Output 20 HP (15 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2955 rpm
Slip 1.50 %
Rated voltage 415 V
Rated current 26.1 A
L. R. Amperes 193 A
LRC 7.4x(Code H)
No load current 9.00 A
Rated torque 35.5 ft.lb
Locked rotor torque 240 %
Breakdown torque 300 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 2.69 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 399 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
89.8  91.1  91.9 

Power factor

50% 75% 100%
0.75  0.83  0.87 
Frame 284/6TS
Output 25 HP (18.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2910 rpm
Slip 3.00 %
Rated voltage 380 V
Rated current 34.9 A
L. R. Amperes 171 A
LRC 4.9x(Code E)
No load current 8.00 A
Rated torque 45.1 ft.lb
Locked rotor torque 160 %
Breakdown torque 200 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 2.69 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 399 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.0  90.2  89.5 

Power factor

50% 75% 100%
0.83  0.88  0.90 
Frame 284/6TS
Output 25 HP (18.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2930 rpm
Slip 2.33 %
Rated voltage 400 V
Rated current 33.3 A
L. R. Amperes 183 A
LRC 5.5x(Code F)
No load current 8.50 A
Rated torque 44.8 ft.lb
Locked rotor torque 180 %
Breakdown torque 220 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 2.69 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 399 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.0  91.0  90.2 

Power factor

50% 75% 100%
0.81  0.87  0.89 
Frame 284/6TS
Output 25 HP (18.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2935 rpm
Slip 2.17 %
Rated voltage 415 V
Rated current 31.8 A
L. R. Amperes 191 A
LRC 6.0x(Code F)
No load current 9.00 A
Rated torque 44.7 ft.lb
Locked rotor torque 190 %
Breakdown torque 240 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 2.69 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 399 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.0  91.0  91.0 

Power factor

50% 75% 100%
0.80  0.86  0.89 

Features

Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole NPT 1 1/2" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Single 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12