Quantity:
IC411 - TEFC, IP55, 284T/286T Frame, 230/460VAC 60Hz 3 Phase, 11441772, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 1-7/8" Keyed Shaft

Electric Motors

Frame 284/6T
Output 20 HP (15 kW)
Number of Poles 6
Frequency 60 Hz
Rated speed 1175 rpm
Slip 2.08 %
Rated voltage 230/460 V
Rated current 48.4/24.2 A
L. R. Amperes 300/150 A
LRC 6.2x(Code G)
No load current 19.0/9.50 A
Rated torque 89.4 ft.lb
Locked rotor torque 229 %
Breakdown torque 260 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 421 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.0  91.7  91.7 

Power factor

50% 75% 100%
0.70  0.80  0.85 
Frame 284/6T
Output 15 HP (11 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 975 rpm
Slip 2.50 %
Rated voltage 380 V
Rated current 21.8 A
L. R. Amperes 135 A
LRC 6.2x(Code G)
No load current 9.40 A
Rated torque 80.8 ft.lb
Locked rotor torque 229 %
Breakdown torque 270 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 421 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
90.0  90.3  90.3 

Power factor

50% 75% 100%
0.66  0.79  0.85 
Frame 284/6T
Output 15 HP (11 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 975 rpm
Slip 2.50 %
Rated voltage 400 V
Rated current 21.2 A
L. R. Amperes 146 A
LRC 6.9x(Code H)
No load current 10.0 A
Rated torque 80.8 ft.lb
Locked rotor torque 270 %
Breakdown torque 290 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 421 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
89.3  90.3  90.3 

Power factor

50% 75% 100%
0.63  0.76  0.83 
Frame 284/6T
Output 15 HP (11 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 980 rpm
Slip 2.00 %
Rated voltage 415 V
Rated current 21.3 A
L. R. Amperes 155 A
LRC 7.3x(Code J)
No load current 10.6 A
Rated torque 80.4 ft.lb
Locked rotor torque 280 %
Breakdown torque 320 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 421 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
89.3  90.6  90.8 

Power factor

50% 75% 100%
0.60  0.73  0.81 
Frame 284/6T
Output 20 HP (15 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 965 rpm
Slip 3.50 %
Rated voltage 380 V
Rated current 29.6 A
L. R. Amperes 139 A
LRC 4.7x(Code E)
No load current 9.40 A
Rated torque 109 ft.lb
Locked rotor torque 170 %
Breakdown torque 200 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 421 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
90.2  90.2  88.5 

Power factor

50% 75% 100%
0.76  0.84  0.87 
Frame 284/6T
Output 20 HP (15 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 970 rpm
Slip 3.00 %
Rated voltage 400 V
Rated current 28.1 A
L. R. Amperes 149 A
LRC 5.3x(Code F)
No load current 10.0 A
Rated torque 108 ft.lb
Locked rotor torque 200 %
Breakdown torque 220 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 421 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
90.2  90.2  89.5 

Power factor

50% 75% 100%
0.73  0.82  0.86 
Frame 284/6T
Output 20 HP (15 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 975 rpm
Slip 2.50 %
Rated voltage 415 V
Rated current 27.2 A
L. R. Amperes 155 A
LRC 5.7x(Code F)
No load current 10.6 A
Rated torque 108 ft.lb
Locked rotor torque 210 %
Breakdown torque 240 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 421 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
90.2  91.0  90.2 

Power factor

50% 75% 100%
0.70  0.80  0.85 

Features

Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole NPT 1 1/2" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Single 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector