We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount/00736ET3E184T-W22 WEG 7.5HP General Purpose Electric Motor, 3600RPM

Product ID: 00736ET3E184T-W22

00736ET3E184T-W22 WEG 7.5HP General Purpose Electric Motor, 3600RPM

MFG: WEG Electric Corporation
MFG Part Number: 00736ET3E184T-W22

Selected accessories will also be added to cart
$805.50 / Each
Quantity:
IC411 - TEFC, IP55, 182T/184T Frame, 208-230/460/380VAC 50/60Hz 3 Phase, 11647930, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 1-1/8" Keyed Shaft

Electric Motors

Frame 182/4T
Output 7.5 HP (5.5 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3485 rpm
Slip 3.19 %
Rated voltage 230/460 V
Rated current 17.5/8.76 A
L. R. Amperes 144/71.8 A
LRC 8.2x(Code J)
No load current 5.80/2.90 A
Rated torque 11.3 ft.lb
Locked rotor torque 270 %
Breakdown torque 330 %
Locked rotor time 30s (cold) 17s (hot)
Moment of inertia (J) 0.2242 sq.ft.lb
Design A
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 66.0 dB(A)
Approx. weight³ 99.2 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
88.5  89.5  89.5 

Power factor

50% 75% 100%
0.75  0.84  0.88 
Frame 182/4T
Output 5.5 HP (4 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2900 rpm
Slip 3.33 %
Rated voltage 380 V
Rated current 7.84 A
L. R. Amperes 65.1 A
LRC 8.3x(Code J)
No load current 2.70 A
Rated torque 9.96 ft.lb
Locked rotor torque 310 %
Breakdown torque 360 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 0.2242 sq.ft.lb
Design A
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 99.2 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
85.5  87.0  88.1 

Power factor

50% 75% 100%
0.70  0.82  0.88 
Frame 182/4T
Output 5.5 HP (4 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2910 rpm
Slip 3.00 %
Rated voltage 400 V
Rated current 7.62 A
L. R. Amperes 69.3 A
LRC 9.1x(Code K)
No load current 3.00 A
Rated torque 9.93 ft.lb
Locked rotor torque 350 %
Breakdown torque 390 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 0.2242 sq.ft.lb
Design A
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 99.2 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
85.9  87.6  88.1 

Power factor

50% 75% 100%
0.66  0.79  0.86 
Frame 182/4T
Output 5.5 HP (4 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2915 rpm
Slip 2.83 %
Rated voltage 415 V
Rated current 7.47 A
L. R. Amperes 71.7 A
LRC 9.6x(Code L)
No load current 3.20 A
Rated torque 9.91 ft.lb
Locked rotor torque 370 %
Breakdown torque 430 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 0.2242 sq.ft.lb
Design A
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 99.2 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
86.2  88.1  88.7 

Power factor

50% 75% 100%
0.63  0.77  0.84 
Frame 182/4T
Output 7.5 HP (5.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2810 rpm
Slip 6.33 %
Rated voltage 380 V
Rated current 10.9 A
L. R. Amperes 68.7 A
LRC 6.3x(Code G)
No load current 2.70 A
Rated torque 14.0 ft.lb
Locked rotor torque 220 %
Breakdown torque 260 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 0.2242 sq.ft.lb
Design A
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 99.2 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
87.0  87.0  84.5 

Power factor

50% 75% 100%
0.80  0.88  0.91 
Frame 182/4T
Output 7.5 HP (5.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2840 rpm
Slip 5.33 %
Rated voltage 400 V
Rated current 10.3 A
L. R. Amperes 72.1 A
LRC 7.0x(Code H)
No load current 3.00 A
Rated torque 13.9 ft.lb
Locked rotor torque 250 %
Breakdown torque 280 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 0.2242 sq.ft.lb
Design A
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 99.2 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
87.5  88.0  86.0 

Power factor

50% 75% 100%
0.77  0.86  0.90 
Frame 182/4T
Output 7.5 HP (5.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2860 rpm
Slip 4.67 %
Rated voltage 415 V
Rated current 10.0 A
L. R. Amperes 74.0 A
LRC 7.4x(Code H)
No load current 3.20 A
Rated torque 13.8 ft.lb
Locked rotor torque 270 %
Breakdown torque 310 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 0.2242 sq.ft.lb
Design A
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 99.2 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
88.0  88.5  87.0 

Power factor

50% 75% 100%
0.74  0.84  0.88 

Features

Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Main terminal box hole NPT 1" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 207A (ISO 12944 - C2) 
Grounding Lugs Single 
Fan Cover material Steel 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap No-Without Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity