Quantity:
IC411 - TEFC, IP55, 184T Frame, 230/460/380VAC 50/60Hz 3 Phase, 12011473, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 1-1/8" Keyed Shaft, F-3 Terminal Box Mounting

Electric Motors

Frame 184T
Output 5 HP (3.7 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1755 rpm
Slip 2.50 %
Rated voltage 230/460 V
Rated current 12.9/6.45 A
L. R. Amperes 96.7/48.4 A
LRC 7.5x(Code J)
No load current 6.40/3.20 A
Rated torque 15.0 ft.lb
Locked rotor torque 229 %
Breakdown torque 320 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 0.4003 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 101 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
88.5  89.5  89.5 

Power factor

50% 75% 100%
0.62  0.74  0.80 
Frame 184T
Output 4 HP (3 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1455 rpm
Slip 3.00 %
Rated voltage 380 V
Rated current 6.42 A
L. R. Amperes 44.9 A
LRC 7.0x(Code J)
No load current 3.15 A
Rated torque 14.4 ft.lb
Locked rotor torque 229 %
Breakdown torque 300 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 0.4003 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 101 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
87.5  88.2  87.7 

Power factor

50% 75% 100%
0.61  0.75  0.81 
Frame 184T
Output 4 HP (3 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1455 rpm
Slip 3.00 %
Rated voltage 400 V
Rated current 6.13 A
L. R. Amperes 47.2 A
LRC 7.7x(Code K)
No load current 3.45 A
Rated torque 14.4 ft.lb
Locked rotor torque 260 %
Breakdown torque 350 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 0.4003 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 101 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
86.7  88.2  88.2 

Power factor

50% 75% 100%
0.57  0.71  0.79 
Frame 184T
Output 4 HP (3 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1460 rpm
Slip 2.67 %
Rated voltage 415 V
Rated current 6.14 A
L. R. Amperes 50.4 A
LRC 8.2x(Code L)
No load current 3.70 A
Rated torque 14.4 ft.lb
Locked rotor torque 290 %
Breakdown torque 380 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 0.4003 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 101 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
86.5  88.2  88.2 

Power factor

50% 75% 100%
0.53  0.67  0.76 
Frame 184T
Output 5 HP (3.7 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1440 rpm
Slip 4.00 %
Rated voltage 380 V
Rated current 7.74 A
L. R. Amperes 44.9 A
LRC 5.8x(Code G)
No load current 3.15 A
Rated torque 18.2 ft.lb
Locked rotor torque 180 %
Breakdown torque 240 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 0.4003 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 101 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
88.5  87.5  86.5 

Power factor

50% 75% 100%
0.69  0.80  0.84 
Frame 184T
Output 5 HP (3.7 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1445 rpm
Slip 3.67 %
Rated voltage 400 V
Rated current 7.44 A
L. R. Amperes 47.6 A
LRC 6.4x(Code H)
No load current 3.45 A
Rated torque 18.2 ft.lb
Locked rotor torque 210 %
Breakdown torque 280 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 0.4003 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 101 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
87.5  88.5  87.5 

Power factor

50% 75% 100%
0.65  0.77  0.82 
Frame 184T
Output 5 HP (3.7 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1450 rpm
Slip 3.33 %
Rated voltage 415 V
Rated current 7.35 A
L. R. Amperes 50.7 A
LRC 6.9x(Code J)
No load current 3.70 A
Rated torque 18.1 ft.lb
Locked rotor torque 229 %
Breakdown torque 300 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 0.4003 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-3
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 101 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
87.5  88.5  87.5 

Power factor

50% 75% 100%
0.61  0.74  0.80 

Features

Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Main terminal box hole NPT 1" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 207A (ISO 12944 - C2) 
Grounding Lugs Single 
Fan Cover material Steel 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap No-Without Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity