We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase Explosion Proof/WEG/C-Face, Foot Mount/00336XT3E182TC WEG 3HP Explosion Proof Electric Motor, 3600RPM

Product ID: 00336XT3E182TC

00336XT3E182TC WEG 3HP Explosion Proof Electric Motor, 3600RPM

MFG: WEG Electric Corporation
MFG Part Number: 00336XT3E182TC

Selected accessories will also be added to cart
$946.50 / Each
Quantity:
IC411 - TEFC, 182TC/184TC Frame, 208-230/460VAC 3-Phase 60Hz, C-Face, Foot Mount, 14212540, NEMA Premium Efficiency
WEG Explosion-proof motor was especially designed to operate in environments with the presence of explosive atmospheres. It has robust construction, a flame retention system with gaps between the parts carefully designed, accurate machining on the terminal box and screws with high mechanical strength. It meets the requirements of explosive atmospheres like Division I/Zone 1. All ratings meet NEMA Premium Efficiency. Motors are certified for VFD service.
Product features
Standard NEMA MG-1
Frequency 60 Hz
Voltage 208-230/460 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3600 rpm
Output rating 3 HP
Mounting Foot-mounted
Flange C
Mounting F-1
Terminal box¹ Left position
Enclosure IC411 - TEFC

Electric Motors

Frame 182/4TC
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3510 rpm
Slip 2.50 %
Rated voltage 208-230/460 V
Rated current 8.32-7.52/3.76 A
L. R. Amperes 69.8-63.2/31.6 A
LRC 8.4x(Code K)
No load current 2.41-2.80/1.40 A
Rated torque 4.43 ft.lb
Locked rotor torque 250 %
Breakdown torque 400 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 0.1471 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 125 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
82.5  85.5  86.5 

Power factor

50% 75% 100%
0.73  0.81  0.85 
Frame 182/4TC
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2880 rpm
Slip 4.00 %
Rated voltage 380 V
Rated current 4.44 A
L. R. Amperes 29.7 A
LRC 6.7x(Code H)
No load current 1.30 A
Rated torque 5.40 ft.lb
Locked rotor torque 210 %
Breakdown torque 300 %
Locked rotor time 77s (cold) 43s (hot)
Moment of inertia (J) 0.1471 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 125 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
82.5  85.5  85.5 

Power factor

50% 75% 100%
0.78  0.85  0.88 
Frame 182/4TC
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2890 rpm
Slip 3.67 %
Rated voltage 400 V
Rated current 4.27 A
L. R. Amperes 31.6 A
LRC 7.4x(Code J)
No load current 1.40 A
Rated torque 5.38 ft.lb
Locked rotor torque 240 %
Breakdown torque 340 %
Locked rotor time 77s (cold) 43s (hot)
Moment of inertia (J) 0.1471 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 125 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
82.5  85.5  86.5 

Power factor

50% 75% 100%
0.75  0.83  0.86 
Frame 182/4TC
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2900 rpm
Slip 3.33 %
Rated voltage 415 V
Rated current 4.16 A
L. R. Amperes 33.3 A
LRC 8.0x(Code J)
No load current 1.48 A
Rated torque 5.36 ft.lb
Locked rotor torque 260 %
Breakdown torque 370 %
Locked rotor time 77s (cold) 43s (hot)
Moment of inertia (J) 0.1471 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 125 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
82.5  85.5  86.5 

Power factor

50% 75% 100%
0.72  0.81  0.85 

Features

Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Main terminal box hole NPT 3/4" 
Terminal Block Without 
Shaft Locking Device Without 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 202P (ISO 12944 - C4) 
Grounding Lugs Single 
Fan Cover material Rolled Steel 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Bolt Material Carbon Steel 
Winding thermal protection Thermostat - 2 wires 1 per phase 155°C 
Balancing Method 1/2 Key 
Drip Cover Without