IC411 - TEFC, IP55, 143JP/145JP Frame, 208-230/460VAC 50/60Hz 3 Phase, 13469733, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame

Electric Motors

Frame 143/5JP
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3460 rpm
Slip 3.89 %
Rated voltage 230/460 V
Rated current 7.42/3.71 A
L. R. Amperes 60.1/30.1 A
LRC 8.1x(Code J)
No load current 2.60/1.30 A
Rated torque 4.55 ft.lb
Locked rotor torque 330 %
Breakdown torque 360 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 0.0605 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 68.0 dB(A)
Approx. weight³ 57.3 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
85.5  86.5  86.5 

Power factor

50% 75% 100%
0.70  0.81  0.86 
Frame 143/5JP
Output 2 HP (1.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2890 rpm
Slip 3.67 %
Rated voltage 380 V
Rated current 3.24 A
L. R. Amperes 27.9 A
LRC 8.6x(Code L)
No load current 1.28 A
Rated torque 3.63 ft.lb
Locked rotor torque 400 %
Breakdown torque 400 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 0.0605 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 57.3 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
81.9  84.0  84.8 

Power factor

50% 75% 100%
0.63  0.76  0.83 
Frame 143/5JP
Output 2 HP (1.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2905 rpm
Slip 3.17 %
Rated voltage 400 V
Rated current 3.17 A
L. R. Amperes 29.2 A
LRC 9.2x(Code M)
No load current 1.43 A
Rated torque 3.62 ft.lb
Locked rotor torque 459 %
Breakdown torque 459 %
Locked rotor time 23s (cold) 13s (hot)
Moment of inertia (J) 0.0605 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 57.3 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
82.0  84.4  85.3 

Power factor

50% 75% 100%
0.58  0.72  0.80 
Frame 143/5JP
Output 2 HP (1.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2910 rpm
Slip 3.00 %
Rated voltage 415 V
Rated current 3.15 A
L. R. Amperes 29.9 A
LRC 9.5x(Code M)
No load current 1.55 A
Rated torque 3.61 ft.lb
Locked rotor torque 490 %
Breakdown torque 509 %
Locked rotor time 23s (cold) 13s (hot)
Moment of inertia (J) 0.0605 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 57.3 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
82.2  84.8  85.9 

Power factor

50% 75% 100%
0.55  0.69  0.77 
Frame 143/5JP
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2820 rpm
Slip 6.00 %
Rated voltage 380 V
Rated current 4.44 A
L. R. Amperes 27.1 A
LRC 6.1x(Code G)
No load current 1.28 A
Rated torque 5.59 ft.lb
Locked rotor torque 260 %
Breakdown torque 260 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 0.0605 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 57.3 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
84.0  85.0  84.6 

Power factor

50% 75% 100%
0.76  0.85  0.89 
Frame 143/5JP
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2840 rpm
Slip 5.33 %
Rated voltage 400 V
Rated current 4.26 A
L. R. Amperes 28.5 A
LRC 6.7x(Code H)
No load current 1.43 A
Rated torque 5.55 ft.lb
Locked rotor torque 300 %
Breakdown torque 300 %
Locked rotor time 23s (cold) 13s (hot)
Moment of inertia (J) 0.0605 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 57.3 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
84.5  85.5  85.6 

Power factor

50% 75% 100%
0.72  0.82  0.87 
Frame 143/5JP
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2850 rpm
Slip 5.00 %
Rated voltage 415 V
Rated current 4.13 A
L. R. Amperes 29.3 A
LRC 7.1x(Code H)
No load current 1.55 A
Rated torque 5.53 ft.lb
Locked rotor torque 320 %
Breakdown torque 330 %
Locked rotor time 23s (cold) 13s (hot)
Moment of inertia (J) 0.0605 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 57.3 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
85.0  86.0  86.2 

Power factor

50% 75% 100%
0.69  0.80  0.86 

Features

Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Main terminal box hole NPT 3/4" 
Terminal Block Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 207A (ISO 12944 - C2) 
Grounding Lugs Single 
Fan Cover material Steel 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Drip Cover Without 
Pump Seal Gasket 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity