We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electrical Components/WEG/Contactors/IEC Contactors (CWM)/CWM105/CWM105-11-30V18 WEG 3-Pole IEC Standard Contactor

Product ID: CWM105-11-30V18

CWM105-11-30V18 WEG 3-Pole IEC Standard Contactor

MFG: WEG Electric Corporation
MFG Part Number: CWM105-11-30V18

Selected accessories will also be added to cart
$177.59 / Each
Quantity:
75HP @ 460V, 120VAC 60Hz Coil, 105 Amp, 1NO/1NC

Description :

The CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories.

Standard Features :

  • Panel mountable or 35mm DIN Rail
  • Front and Side Mounting Auxiliary Contacts
  • Finger-Touch IP20 Protection
  • Wide Coil Voltage Protection AC or DC
  • Mirror Contacts for “Safety-Related” Applications
  • Mechanically linked Auxiliary Contacts

Overview :

Brand WEG
Catalog Number(s) CWM105-11-30V18
Type CWM105
Auxiliary Contacts 1 Normally Open
1 Normally Closed
Current Rating 105 Amps
Coil Voltage 120VAC 60Hz
Power Poles 3
Operating Temperature -25 to +55°C
-13 to +131°F
Terminals Allen Head
5/32” (4mm) Drive Size
44.3-57.5 lb-in (5-6.5 Nm)
Terminal Capacity Top: 16-1 AWG
Bottom: 10-2 AWG
UPC 7890355021378
Weight 3.30 lbs

Control Circuit Ratings – AC Coil :

Rated Insulation Voltage (Ui) IEC; VDE 0660: 1000 Volts
UL; CSA: 600 Volts
Rated Operating Voltage (Ue) IEC; VDE 0660: 690 Volts
UL; CSA: 600 Volts
Coil Operating Limits Pick-up xUc:
Drop-out xUc:
Operating Time Coil Energization – N.O.:
Coil de-energization – N.O.:
Coil Consumption Sealed:
Inrush:
Thermal Power Dissipation 60Hz:
Power Factor Closed:
Opened:
Stranded / Solid (UL / CSA) 2x12-10 AWG

Standard UL/CSA Ratings :

Rated Operating Voltage 600 Volts
General Purpose Amp Rating (AC-1) 140 Amps
Rated Operational Power, Single Phase, Full Voltage 50/60Hz 10 HP or 100 Amps @ 115VAC
20 HP or 88 Amps @ 230VAC
Rated Operational Power, Three Phase, Full Voltage 50/60Hz 30 HP or 92 Amps @ 200VAC
40 HP or 104 Amps @ 230VAC
75 HP or 96 Amps @ 460VAC
75 HP or 77 Amps @ 575VAC
Short Circuit Rating 10 kA @ 600V

Standard IEC Ratings (IEC EN 60947) :

Rated Operating Voltage 1000 Volts
Rated Thermal Current Ith 140 Amps
Rated Operational Power, Three Phase, AC-3, 50/60Hz 30kW or 105 Amps @ 220-240V
55kW or 105 Amps @ 380-400V
55kW or 105 Amps @ 415-440V
65kW or 85 Amps @ 500V
65kW or 80 Amps @ 660-690V
Maximum Switch Rate AC-1: 1,200 ops/hr
AC-3: 600 ops/hr
No Load: 5,000 ops/hr
AC-4 (200,000 Operations; 50/60Hz) 12.5kW/17HP @ 220-230V
22kW/30HP @ 380-400V
30kW/40HP @ 415-440V
30kW/40HP @ 500V
33kW/45HP @ 660-690V
50 Amps @ ≥ 690V
Breaking Capacity Ue=400V: 1050 Amps
Ue=500V: 1050 Amps
Ue=690V: 950 Amps
Impedance Per Pole 0.76 mW
Power Dissipation per Pole AC-1: 14.89 W
AC-3: 8.37 W
Short Time Current Icw 1 Second: 3,300 Amps
5 Seconds: 1,485 Amps
10 Seconds: 1,050 Amps
30 Seconds: 600Amps
1 Minute: 430 Amps
3 Minutes: 250 Amps
Rec. Time: 10 minutes
Short Circuit Coordination Coordination Type “1”: 250 gL/gG
Coordination Type “2”: 200 gL/gG
Acc. To UL/CSA: 200 J Type