We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/Single Phase, Explosion Proof/Baldor/Foot Mount, C-Face/CL5013 Baldor 1.5HP Explosion Proof Electric Motor, 1800RPM

Product ID: CL5013

CL5013 Baldor 1.5HP Explosion Proof Electric Motor, 1800RPM

MFG: Baldor Electric Company
MFG Part Number: CL5013

Selected accessories will also be added to cart
$1,699.97 / Each
Quantity:
XPFC, 184C Frame, 115/230VAC Single Phase 60Hz, C-Face, Foot Mount, 7/8" Keyed Shaft

Specifications

Specs

Output 1.500 hp
Phase 1
Synchronous Speed 1,800 rpm
Frequency 60.00 Hz
Voltage 115 V
230 V
Frame Material Steel
Frame 184C
XP Class and Group Class I, Group D; Class II, Group F & G
XP Division Division I
Brand Baldor-Reliance
Agency Approvals CSA
UL
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Auxillary Box Lead Termination None
Base Indicator Rigid
Bearing Grease Type POLYREX EM (-20F +300F)
Blower None
Current 19.0 A @ 115 V
9.5 A @ 230 V
Design Code L
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 70.0%
Electrically Isolated Bearing Not Electrically Isolated
Feedback Device No feedback
Front Face Code Standard
Front Shaft Indicator None
Heater Indicator No heater
High Voltage Full Load Amps 9.5 A
Insulation Class B
Inverter Code Not inverter
KVA Code L
Lifting Lugs No Lifting Lugs
Locked Bearing Indicator No Locked Bearing
Motor Lead Exit KO Box
Motor Lead Quantity/Wire Size 4 @ 14 AWG, A PH
Motor Lead Termination Flying Leads
Motor Standards NEMA
Motor Type X3628L
Number of Poles 4
Overall Length 16.93 in
Power Factor 70
Product Family General Purpose
Pulley End Bearing Type Ball
Pulley Face Code C-Face
Pulley Shaft Indicator Standard
Rodent Screen None
Service Factor 1.00
Shaft Diameter 0.875 in
Shaft Extension Location Pulley End
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Shaft Slinger Indicator No Slinger
Speed 1,725 rpm
Speed Code Single Speed
Starting Method Direct on line
Thermal Device - Bearing None
Thermal Device - Winding Normally Closed Thermostat
Vibration Sensor Indicator No Vibration Sensor
Winding Thermal 1 None
Winding Thermal 2 None
XP Temp Code T3C

Applications

  • Customer specified Division 1 hazardous areas
  • Pumps, fans and conveyors
  • Fixed speed operation

Features

  • Robust steel and cast iron frame designs
  • Auto thermal overload (<1 Hp), normally closed thermostats (>1 Hp)
  • Threaded lead inlet
  • Low noise vibration dampening bases

Nameplate

Nameplate

NO. CC
SER.
SPEC. 36N11-79G1
CAT.NO. CL5013
HP 1.5 T. CODE T3C
VOLTS 115/230
AMPS 19/9.5
RPM 1725
HZ 60 PH 1 CL B
SER.F. 1.00 DES L CODE L
RATING 40C AMB-CONT
FRAME 184C NEMA-NOM-EFF 70
USABLE AT 208V PF 70
BLANK
NP1426XPSL

Performance

Performance

Performance at 230 V, 60 Hz, 1.5 hp

Typical performance; not guaranteed values.

General Characteristics

Full Load Torque 0 LB-FT
No-Load Current 0 A
Line-Line Res. @ 25° C 1.16 Ohms A Ph / 0.581 Ohms B Ph
Temp. Rise @ Rated Load 67° C
Temp. Rise @ S.F. Load
Start Configuration DOL
Break-Down Torque 14 LB-FT
Pull-Up Torque 12 LB-FT
Locked-Rotor Torque 16 LB-FT
Starting Current 68 A

Load Characteristics

Rated Load 0% 25% 50% 75% 100% 125% 150% S.F.
Power Factor 18.0 38.0 50.0 61.0 68.0 75.0 79.0 0.0
Efficiency 0.0 56.2 66.9 72.6 77.7 76.2 72.8 0.0
Speed (RPM) 1,798 1,784 1,776 1,764 1,754 1,742 1,727 0
Line Amps 7.10 7.30 7.80 8.80 9.60 10.90 12.60 10.40

Performance Curves