We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount/40036ET3G449TS-W22 WEG 400HP General Purpose Electric Motor, 3600RPM

Product ID: 40036ET3G449TS-W22

40036ET3G449TS-W22 WEG 400HP General Purpose Electric Motor, 3600RPM

MFG: WEG Electric Corporation
MFG Part Number: 40036ET3G449TS-W22

Selected accessories will also be added to cart
$33,453.75 / Each
Quantity:
IC411 - TEFC, IP55, L447TS/L449TS Frame, 460VAC 60Hz 3 Phase, 11408289, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 2-3/8" Keyed Shaft

Electric Motors

Frame L447/9TS
Output 400 HP (300 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3583 rpm
Slip 0.47 %
Rated voltage 460 V
Rated current 442 A
L. R. Amperes 4066 A
LRC 9.2x(Code K)
No load current 118 A
Rated torque 586 ft.lb
Locked rotor torque 260 %
Breakdown torque 290 %
Locked rotor time 39s (cold) 22s (hot)
Moment of inertia (J) 91.9 sq.ft.lb
Design A
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 88.0 dB(A)
Approx. weight³ 3185 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.4  95.8  95.8 

Power factor

50% 75% 100%
0.80  0.85  0.89 
Frame L447/9TS
Output 350 HP (260 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2982 rpm
Slip 0.60 %
Rated voltage 380 V
Rated current 458 A
L. R. Amperes 3618 A
LRC 7.9x(Code H)
No load current 115 A
Rated torque 616 ft.lb
Locked rotor torque 250 %
Breakdown torque 260 %
Locked rotor time 43s (cold) 24s (hot)
Moment of inertia (J) 91.9 sq.ft.lb
Design A
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 86.0 dB(A)
Approx. weight³ 3185 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.4  95.8  95.8 

Power factor

50% 75% 100%
0.80  0.85  0.90 
Frame L447/9TS
Output 350 HP (260 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2984 rpm
Slip 0.53 %
Rated voltage 400 V
Rated current 435 A
L. R. Amperes 3872 A
LRC 8.9x(Code J)
No load current 122 A
Rated torque 616 ft.lb
Locked rotor torque 270 %
Breakdown torque 290 %
Locked rotor time 39s (cold) 22s (hot)
Moment of inertia (J) 91.9 sq.ft.lb
Design A
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 86.0 dB(A)
Approx. weight³ 3185 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.4  95.8  95.8 

Power factor

50% 75% 100%
0.80  0.85  0.90 
Frame L447/9TS
Output 350 HP (260 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2985 rpm
Slip 0.50 %
Rated voltage 415 V
Rated current 424 A
L. R. Amperes 4070 A
LRC 9.6x(Code K)
No load current 129 A
Rated torque 616 ft.lb
Locked rotor torque 290 %
Breakdown torque 320 %
Locked rotor time 37s (cold) 21s (hot)
Moment of inertia (J) 91.9 sq.ft.lb
Design A
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 86.0 dB(A)
Approx. weight³ 3185 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.4  95.8  95.8 

Power factor

50% 75% 100%
0.78  0.85  0.89 

Features

Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System Extended, at Drive end and Non-drive end 
Main terminal box hole 2xNPT 3" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 4140 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12