We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount/12536ET3E444TS-W22 WEG 125HP General Purpose Electric Motor, 3600RPM

Product ID: 12536ET3E444TS-W22

12536ET3E444TS-W22 WEG 125HP General Purpose Electric Motor, 3600RPM

MFG: WEG Electric Corporation
MFG Part Number: 12536ET3E444TS-W22

Selected accessories will also be added to cart
$11,512.50 / Each
Quantity:
IC411 - TEFC, IP55, 444TS/445TS Frame, 230/460VAC 60Hz 3 Phase, 11611958, Foot Mounted, NEMA Premium Efficiency, Cast Iron Frame, 2-3/8" Keyed Shaft

Electric Motors

Frame 444/5TS
Output 125 HP
Number of Poles 2
Frequency 60 Hz
Rated speed 3570 rpm
Slip 0.83 %
Rated voltage 230/460 V
Rated current 268/134 A
L. R. Amperes 1769/884 A
LRC 6.6x(Code G)
No load current 68.0/34.0 A
Rated torque 184 ft.lb
Locked rotor torque 200 %
Breakdown torque 250 %
Locked rotor time 52s (cold) 29s (hot)
Moment of inertia (J) 33.5 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 81.0 dB(A)
Approx. weight³ 1631 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.6  94.5  95.0 

Power factor

50% 75% 100%
0.82  0.87  0.89 
Frame 444/5TS
Output 100 HP (75 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2970 rpm
Slip 1.00 %
Rated voltage 380 V
Rated current 135 A
L. R. Amperes 878 A
LRC 6.5x(Code G)
No load current 33.6 A
Rated torque 177 ft.lb
Locked rotor torque 200 %
Breakdown torque 250 %
Locked rotor time 36s (cold) 20s (hot)
Moment of inertia (J) 33.5 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 1631 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.2  94.3  94.7 

Power factor

50% 75% 100%
0.79  0.87  0.89 
Frame 444/5TS
Output 100 HP (75 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2970 rpm
Slip 1.00 %
Rated voltage 400 V
Rated current 128 A
L. R. Amperes 909 A
LRC 7.1x(Code G)
No load current 36.0 A
Rated torque 177 ft.lb
Locked rotor torque 210 %
Breakdown torque 280 %
Locked rotor time 36s (cold) 20s (hot)
Moment of inertia (J) 33.5 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 1631 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.2  94.3  94.7 

Power factor

50% 75% 100%
0.77  0.87  0.89 
Frame 444/5TS
Output 100 HP (75 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2975 rpm
Slip 0.83 %
Rated voltage 415 V
Rated current 124 A
L. R. Amperes 955 A
LRC 7.7x(Code H)
No load current 37.9 A
Rated torque 177 ft.lb
Locked rotor torque 240 %
Breakdown torque 300 %
Locked rotor time 36s (cold) 20s (hot)
Moment of inertia (J) 33.5 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 1631 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.8  94.3  94.8 

Power factor

50% 75% 100%
0.75  0.85  0.89 
Frame 444/5TS
Output 125 HP
Number of Poles 2
Frequency 50 Hz
Rated speed 2960 rpm
Slip 1.33 %
Rated voltage 380 V
Rated current 163 A
L. R. Amperes 848 A
LRC 5.2x(Code D)
No load current 33.6 A
Rated torque 222 ft.lb
Locked rotor torque 160 %
Breakdown torque 200 %
Locked rotor time 36s (cold) 20s (hot)
Moment of inertia (J) 33.5 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 1631 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.0  94.5  94.5 

Power factor

50% 75% 100%
0.85  0.88  0.89 
Frame 444/5TS
Output 125 HP
Number of Poles 2
Frequency 50 Hz
Rated speed 2965 rpm
Slip 1.17 %
Rated voltage 400 V
Rated current 154 A
L. R. Amperes 878 A
LRC 5.7x(Code E)
No load current 36.0 A
Rated torque 221 ft.lb
Locked rotor torque 170 %
Breakdown torque 220 %
Locked rotor time 36s (cold) 20s (hot)
Moment of inertia (J) 33.5 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 1631 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.0  94.5  94.5 

Power factor

50% 75% 100%
0.84  0.88  0.89 
Frame 444/5TS
Output 125 HP
Number of Poles 2
Frequency 50 Hz
Rated speed 2970 rpm
Slip 1.00 %
Rated voltage 415 V
Rated current 148 A
L. R. Amperes 918 A
LRC 6.2x(Code F)
No load current 37.9 A
Rated torque 221 ft.lb
Locked rotor torque 190 %
Breakdown torque 240 %
Locked rotor time 36s (cold) 20s (hot)
Moment of inertia (J) 33.5 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 1631 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.0  94.5  95.0 

Power factor

50% 75% 100%
0.82  0.87  0.89 

Features

Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole 2xNPT 3" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector