We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount/12512ET3G445T-W22 WEG 125HP General Purpose Electric Motor, 1200RPM

Product ID: 12512ET3G445T-W22

12512ET3G445T-W22 WEG 125HP General Purpose Electric Motor, 1200RPM

MFG: WEG Electric Corporation
MFG Part Number: 12512ET3G445T-W22

Selected accessories will also be added to cart
$13,460.25 / Each
Quantity:
IC411 - TEFC, IP55, 444T/445T Frame, 460VAC 60Hz 3 Phase, 11356033, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 3-3/8" Keyed Shaft

Electric Motors

Frame 444/5T
Output 125 HP
Number of Poles 6
Frequency 60 Hz
Rated speed 1185 rpm
Slip 1.25 %
Rated voltage 460 V
Rated current 143 A
L. R. Amperes 915 A
LRC 6.4x(Code G)
No load current 56.0 A
Rated torque 554 ft.lb
Locked rotor torque 210 %
Breakdown torque 240 %
Locked rotor time 34s (cold) 19s (hot)
Moment of inertia (J) 104 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 1802 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.0  95.4  95.0 

Power factor

50% 75% 100%
0.70  0.79  0.83 
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 380 V
Rated current 143 A
L. R. Amperes 915 A
LRC 6.4x(Code G)
No load current 55.4 A
Rated torque 533 ft.lb
Locked rotor torque 200 %
Breakdown torque 240 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 104 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 65.0 dB(A)
Approx. weight³ 1802 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.8  94.9  94.6 

Power factor

50% 75% 100%
0.68  0.79  0.84 
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 400 V
Rated current 138 A
L. R. Amperes 980 A
LRC 7.1x(Code H)
No load current 59.3 A
Rated torque 533 ft.lb
Locked rotor torque 229 %
Breakdown torque 260 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 104 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 65.0 dB(A)
Approx. weight³ 1802 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.7  94.9  94.6 

Power factor

50% 75% 100%
0.65  0.77  0.83 
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 415 V
Rated current 130 A
L. R. Amperes 991 A
LRC 7.6x(Code J)
No load current 62.3 A
Rated torque 533 ft.lb
Locked rotor torque 250 %
Breakdown torque 290 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 104 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 65.0 dB(A)
Approx. weight³ 1802 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
94.7  95.1  94.8 

Power factor

50% 75% 100%
0.62  0.75  0.81 
Frame 444/5T
Output 125 HP
Number of Poles 6
Frequency 50 Hz
Rated speed 980 rpm
Slip 2.00 %
Rated voltage 380 V
Rated current 172 A
L. R. Amperes 877 A
LRC 5.1x(Code E)
No load current 55.4 A
Rated torque 670 ft.lb
Locked rotor torque 160 %
Breakdown torque 190 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 104 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 65.0 dB(A)
Approx. weight³ 1802 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.0  94.5  93.6 

Power factor

50% 75% 100%
0.76  0.82  0.85 
Frame 444/5T
Output 125 HP
Number of Poles 6
Frequency 50 Hz
Rated speed 980 rpm
Slip 2.00 %
Rated voltage 400 V
Rated current 165 A
L. R. Amperes 941 A
LRC 5.7x(Code F)
No load current 59.3 A
Rated torque 670 ft.lb
Locked rotor torque 180 %
Breakdown torque 210 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 104 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 65.0 dB(A)
Approx. weight³ 1802 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.0  94.5  93.6 

Power factor

50% 75% 100%
0.73  0.81  0.84 
Frame 444/5T
Output 125 HP
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 415 V
Rated current 160 A
L. R. Amperes 992 A
LRC 6.2x(Code G)
No load current 62.3 A
Rated torque 666 ft.lb
Locked rotor torque 200 %
Breakdown torque 229 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 104 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 65.0 dB(A)
Approx. weight³ 1802 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
95.0  95.0  94.1 

Power factor

50% 75% 100%
0.70  0.79  0.83 

Features

Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole 2xNPT 3" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 4140 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12