We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/IEEE 841/Foot Mount/06036ST3QIE364TS-W22 WEG 60HP Severe Duty Electric Motor, 3600RPM

Product ID: 06036ST3QIE364TS-W22

06036ST3QIE364TS-W22 WEG 60HP Severe Duty Electric Motor, 3600RPM

MFG: WEG Electric Corporation
MFG Part Number: 06036ST3QIE364TS-W22

Selected accessories will also be added to cart
$6,498.75 / Each
Quantity:
IC411 - TEFC, IP55, 364TS/365TS Frame, 460VAC 60Hz 3 Phase, 11431671, NEMA Premium Efficiency, IEEE 841, Foot Mounted, Cast Iron Frame, 1-7/8" Keyed Shaft

Electric Motors

Frame 364/5TS
Output 60 HP (45 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3550 rpm
Slip 1.39 %
Rated voltage 460 V
Rated current 67.0 A
L. R. Amperes 429 A
LRC 6.4x(Code G)
No load current 15.0 A
Rated torque 88.8 ft.lb
Locked rotor torque 190 %
Breakdown torque 250 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 10.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 79.0 dB(A)
Approx. weight³ 864 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.7  93.0  93.6 

Power factor

50% 75% 100%
0.81  0.88  0.90 
Frame 364/5TS
Output 50 HP (37 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2945 rpm
Slip 1.83 %
Rated voltage 380 V
Rated current 66.6 A
L. R. Amperes 406 A
LRC 6.1x(Code F)
No load current 15.0 A
Rated torque 89.2 ft.lb
Locked rotor torque 180 %
Breakdown torque 240 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 10.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 74.0 dB(A)
Approx. weight³ 864 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.1  92.8  92.8 

Power factor

50% 75% 100%
0.81  0.88  0.91 
Frame 364/5TS
Output 50 HP (37 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2950 rpm
Slip 1.67 %
Rated voltage 400 V
Rated current 63.7 A
L. R. Amperes 433 A
LRC 6.8x(Code G)
No load current 16.2 A
Rated torque 89.0 ft.lb
Locked rotor torque 210 %
Breakdown torque 270 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 10.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 74.0 dB(A)
Approx. weight³ 864 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.7  92.8  93.1 

Power factor

50% 75% 100%
0.79  0.87  0.90 
Frame 364/5TS
Output 50 HP (37 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2955 rpm
Slip 1.50 %
Rated voltage 415 V
Rated current 62.1 A
L. R. Amperes 447 A
LRC 7.2x(Code H)
No load current 17.4 A
Rated torque 88.9 ft.lb
Locked rotor torque 220 %
Breakdown torque 290 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 10.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 74.0 dB(A)
Approx. weight³ 864 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.6  92.9  93.1 

Power factor

50% 75% 100%
0.76  0.85  0.89 
Frame 364/5TS
Output 60 HP (45 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2935 rpm
Slip 2.17 %
Rated voltage 380 V
Rated current 81.3 A
L. R. Amperes 407 A
LRC 5.0x(Code D)
No load current 15.0 A
Rated torque 107 ft.lb
Locked rotor torque 150 %
Breakdown torque 200 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 10.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 74.0 dB(A)
Approx. weight³ 864 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  93.0  92.4 

Power factor

50% 75% 100%
0.85  0.90  0.91 
Frame 364/5TS
Output 60 HP (45 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2940 rpm
Slip 2.00 %
Rated voltage 400 V
Rated current 77.6 A
L. R. Amperes 435 A
LRC 5.6x(Code F)
No load current 16.2 A
Rated torque 107 ft.lb
Locked rotor torque 170 %
Breakdown torque 220 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 10.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 74.0 dB(A)
Approx. weight³ 864 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  93.0  93.0 

Power factor

50% 75% 100%
0.83  0.89  0.90 
Frame 364/5TS
Output 60 HP (45 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2945 rpm
Slip 1.83 %
Rated voltage 415 V
Rated current 74.8 A
L. R. Amperes 449 A
LRC 6.0x(Code F)
No load current 17.4 A
Rated torque 107 ft.lb
Locked rotor torque 180 %
Breakdown torque 240 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 10.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 74.0 dB(A)
Approx. weight³ 864 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  93.0  93.0 

Power factor

50% 75% 100%
0.81  0.88  0.90 

Features

Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System Extended in Stainless Steel, at Drive end and Non-drive end 
Main terminal box hole NPT 3" 
Terminal Block Without 
Drain Type T, Threaded 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 202E (ISO 12944 - C4) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting According to IEEE-841 (96h) 
Joints Seal Molykote 
Foot flatness (0.005 pol) 0.127 mm 
Fan material Conductive Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector