We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount, C-Face/05018ET3E326TC-W22 WEG 50HP General Purpose Electric Motor, 1800RPM

Product ID: 05018ET3E326TC-W22

05018ET3E326TC-W22 WEG 50HP General Purpose Electric Motor, 1800RPM

MFG: WEG Electric Corporation
MFG Part Number: 05018ET3E326TC-W22

Selected accessories will also be added to cart
$3,915.75 / Each
Quantity:
IC411 - TEFC, IP55, 324TC/326TC Frame, 230/460VAC 60Hz 3 Phase, 11438075, NEMA Premium Efficiency, Foot Mounted, C-Face, Cast Iron Frame, 2-1/8" Keyed Shaft

Electric Motors

Frame 324/6TC
Output 50 HP (37 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1775 rpm
Slip 1.39 %
Rated voltage 230/460 V
Rated current 118/59.2 A
L. R. Amperes 734/367 A
LRC 6.2x(Code G)
No load current 47.0/23.5 A
Rated torque 148 ft.lb
Locked rotor torque 229 %
Breakdown torque 270 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 66.0 dB(A)
Approx. weight³ 610 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.0  94.1  94.5 

Power factor

50% 75% 100%
0.66  0.77  0.83 
Frame 324/6TC
Output 40 HP (30 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 380 V
Rated current 58.7 A
L. R. Amperes 376 A
LRC 6.4x(Code G)
No load current 23.0 A
Rated torque 143 ft.lb
Locked rotor torque 229 %
Breakdown torque 260 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 610 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.5  93.1  93.6 

Power factor

50% 75% 100%
0.64  0.77  0.83 
Frame 324/6TC
Output 40 HP (30 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 400 V
Rated current 57.1 A
L. R. Amperes 400 A
LRC 7.0x(Code H)
No load current 24.0 A
Rated torque 142 ft.lb
Locked rotor torque 250 %
Breakdown torque 300 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 610 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.5  92.8  93.6 

Power factor

50% 75% 100%
0.60  0.73  0.81 
Frame 324/6TC
Output 40 HP (30 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1478 rpm
Slip 1.47 %
Rated voltage 415 V
Rated current 56.4 A
L. R. Amperes 417 A
LRC 7.4x(Code J)
No load current 25.0 A
Rated torque 142 ft.lb
Locked rotor torque 260 %
Breakdown torque 330 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 610 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.5  93.0  93.6 

Power factor

50% 75% 100%
0.57  0.70  0.79 
Frame 324/6TC
Output 50 HP (37 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1460 rpm
Slip 2.67 %
Rated voltage 380 V
Rated current 71.6 A
L. R. Amperes 372 A
LRC 5.2x(Code E)
No load current 23.0 A
Rated torque 180 ft.lb
Locked rotor torque 180 %
Breakdown torque 210 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 610 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.0  93.0  92.4 

Power factor

50% 75% 100%
0.72  0.81  0.85 
Frame 324/6TC
Output 50 HP (37 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1465 rpm
Slip 2.33 %
Rated voltage 400 V
Rated current 68.4 A
L. R. Amperes 397 A
LRC 5.8x(Code F)
No load current 24.0 A
Rated torque 179 ft.lb
Locked rotor torque 200 %
Breakdown torque 240 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 610 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  93.0  93.0 

Power factor

50% 75% 100%
0.68  0.79  0.84 
Frame 324/6TC
Output 50 HP (37 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 415 V
Rated current 66.3 A
L. R. Amperes 411 A
LRC 6.2x(Code G)
No load current 25.0 A
Rated torque 179 ft.lb
Locked rotor torque 210 %
Breakdown torque 260 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 610 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  93.0  93.5 

Power factor

50% 75% 100%
0.65  0.76  0.83 

Features

Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole NPT 2" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Single 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector