We are now required to collect sales tax in Florida, Iowa, New Jersey & Ohio. If you are tax exempt, please create an account and send us your sales tax exemption form before placing an order. MORE INFO
/Products/Electric Motors/3 Phase/WEG/W22 General Purpose, TEFC/Foot Mount, C-Face/04018ET3E324TC-W22 WEG 40HP General Purpose Electric Motor, 1800RPM

Product ID: 04018ET3E324TC-W22

04018ET3E324TC-W22 WEG 40HP General Purpose Electric Motor, 1800RPM

MFG: WEG Electric Corporation
MFG Part Number: 04018ET3E324TC-W22

Selected accessories will also be added to cart
$3,225.00 / Each
Quantity:
IC411 - TEFC, IP55, 324TC/326TC Frame, 230/460VAC 60Hz 3 Phase, 12447129, NEMA Premium Efficiency, Foot Mounted, C-Face, Cast Iron Frame, 2-1/8" Keyed Shaft

Electric Motors

Frame 324/6TC
Output 40 HP (30 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1770 rpm
Slip 1.67 %
Rated voltage 230/460 V
Rated current 94.2/47.1 A
L. R. Amperes 575/287 A
LRC 6.1x(Code G)
No load current 34.0/17.0 A
Rated torque 119 ft.lb
Locked rotor torque 229 %
Breakdown torque 240 %
Locked rotor time 36s (cold) 20s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 66.0 dB(A)
Approx. weight³ 590 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.6  94.1  94.1 

Power factor

50% 75% 100%
0.72  0.80  0.85 
Frame 324/6TC
Output 30 HP (22 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 380 V
Rated current 42.8 A
L. R. Amperes 282 A
LRC 6.6x(Code G)
No load current 16.8 A
Rated torque 107 ft.lb
Locked rotor torque 240 %
Breakdown torque 260 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 590 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.9  93.1  93.0 

Power factor

50% 75% 100%
0.68  0.78  0.84 
Frame 324/6TC
Output 30 HP (22 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1480 rpm
Slip 1.33 %
Rated voltage 400 V
Rated current 41.6 A
L. R. Amperes 304 A
LRC 7.3x(Code H)
No load current 17.3 A
Rated torque 106 ft.lb
Locked rotor torque 270 %
Breakdown torque 290 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 590 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
92.4  93.0  93.2 

Power factor

50% 75% 100%
0.64  0.75  0.82 
Frame 324/6TC
Output 30 HP (22 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1480 rpm
Slip 1.33 %
Rated voltage 415 V
Rated current 41.1 A
L. R. Amperes 316 A
LRC 7.7x(Code J)
No load current 18.6 A
Rated torque 106 ft.lb
Locked rotor torque 280 %
Breakdown torque 310 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 590 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
91.7  92.6  93.1 

Power factor

50% 75% 100%
0.62  0.73  0.80 
Frame 324/6TC
Output 40 HP (30 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1460 rpm
Slip 2.67 %
Rated voltage 380 V
Rated current 57.4 A
L. R. Amperes 287 A
LRC 5.0x(Code E)
No load current 16.8 A
Rated torque 144 ft.lb
Locked rotor torque 170 %
Breakdown torque 180 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 590 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.6  93.0  92.4 

Power factor

50% 75% 100%
0.78  0.84  0.86 
Frame 324/6TC
Output 40 HP (30 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1465 rpm
Slip 2.33 %
Rated voltage 400 V
Rated current 54.1 A
L. R. Amperes 303 A
LRC 5.6x(Code F)
No load current 17.3 A
Rated torque 143 ft.lb
Locked rotor torque 190 %
Breakdown torque 210 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 590 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.6  93.0  93.0 

Power factor

50% 75% 100%
0.74  0.82  0.86 
Frame 324/6TC
Output 40 HP (30 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 415 V
Rated current 52.8 A
L. R. Amperes 317 A
LRC 6.0x(Code G)
No load current 18.6 A
Rated torque 143 ft.lb
Locked rotor torque 210 %
Breakdown torque 229 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 9.16 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 590 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
93.0  93.0  93.0 

Power factor

50% 75% 100%
0.72  0.80  0.85 

Features

Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole NPT 2" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Single 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector